Repeatable procedures used by lab sessions and telemetry runs.
Recipe definition
Recipe library
4 recipes
PowerLink X1 Lab Proof
PowerLink X1 lab proof
Capture a complete bench record of receiver behavior under a controlled transmit source.
1. Log receiver and transmitter IDs.
2. Set source and record TX level.
3. Fix distance and alignment.
4. Record measured output.
5. Record load battery before/after and run time.
6. Record receiver and ambient temperature.
7. Store evidence (photo/scope capture) and link location.
Pass: All proof fields populated with measured values and reviewed to Pass. No TBD entries.
Frequency Sweep
frequency sweep
Characterize receiver response across the target band.
Step frequency across band at fixed distance and record output at each point.
Pass: Continuous curve recorded with no unexplained dropouts.
Alignment Sensitivity
alignment sensitivity
Measure output falloff versus angular and lateral misalignment.
Hold distance constant, vary offset in fixed increments, record output.
Pass: Falloff curve recorded across full offset range.
Thermal Stability
thermal stability
Track receiver temperature over a sustained run.
Run continuously and log receiver and ambient temperature at fixed intervals.
Pass: Temperature logged for full duration with no thermal excursion.